MOLDED CASE CIRCUIT BREAKER (MCCB) FUJI ELECTRIC

MOLDED CASE CIRCUIT BREAKER (MCCB) FUJI ELECTRIC

MCCB BW Series Fuji Electric focusing on assembly of easy wiring, maintenance check, reasonable price, and standardized distribution board design, BW series MCCBs are designed mainly for building construction market and secondary distribution market.

1.    MCCB BW Series 32AF Fuji Electric

•    Nominal Current (ln) 3A s/d 32A
•    Termination Capacity 1.5kA, 2.5kA
•    Fixed Type
•    Standard IEC 60947-2

2.    MCCB BW Series 50AF, 63AF Fuji Electric

•    Nominal Current (ln) 5A s/d 63A
•    Termination Capacity 2.5kA, 7.5kA, 10kA
•    Fixed Type
•    Standard IEC 60947-2

3.    MCCB BW, BWE0, BWS0 Series 100AF Fuji Electric

•    Nominal Current (ln) 15A s/d 100A
•    Termination Capacity 10kA, 18kA, 30kA
•    Fixed Type
•    Standard IEC 60947-2

4.    MCCB BW Series 125AF Fuji Electric

•    Nominal Current (ln) 15A s/d 125A
•    Termination Capacity 30kA, 36kA, 50kA, 65kA
•    Fixed Type
•    Standard IEC 60947-2

5.    MCCB BW Series 160AF Fuji Electric

•    Nominal Current (ln) 125A s/d 160A
•    Termination Capacity 18kA, 30kA, 36kA, 50kA
•    Fixed Type
•    Standard IEC 60947-2

6.    MCCB BW Series 250AF Fuji Electric

•    Nominal Current (ln) 175A s/d 250A
•    Termination Capacity 18kA, 30kA, 36kA, 50kA, 65kA
•    Fixed Type
•    Standard IEC 60947-2

7.    MCCB BW Series 400AF Fuji Electric

•    Nominal Current (ln) 250A s/d 400A
•    Termination Capacity 30kA, 36kA, 50kA, 70kA
•    Fixed Type
•    Standard IEC 60947-2

8.    MCCB BW Series 630AF Fuji Electric

•    Nominal Current (ln) 500A s/d 630A
•    Termination Capacity 36kA, 50kA, 70kA
•    Fixed Type
•    Standard IEC 60947-2

9.    MCCB BW Series 800AF Fuji Electric

•    Nominal Current (ln) 700A s/d 800A
•    Termination Capacity 36kA, 50kA, 70kA
•    Fixed Type
•    Standard IEC 60947-2

10.  Aksesoris MCCB Internal 32AF – 100AF Fuji Electric

Aksesoris Internal for MCCB BW32, BW50, BW63, BW100 Fuji Electric

  • Auxiliary Switch (Type W)
    This switch is used for indicator lamp or control circuit.
  • Alarm Switch (Type K)
    This switch can be connected  to a warning lamp or buzzer to indicate when the breaker has been tripped.
  • Shunt Trip Device (Type F)
    The puspose of this accessory is to trip the breaker from a distance.
  • Undervoltage Trip Device (Type R)
    The device is designed to protect circuits from harmful voltage drops. It can also be used for remote control purposes. The trip operates when the voltage drops to less than 70% of nominal coil rating, and the breaker cannot be reset until the voltage recovers 85% of its normal rating.
  • Terminal Block (Type A)
    A wiring terminal for internal accessories (Order with W, K or F)

11.    Aksesoris MCCB Internal 125AF – 800AF Fuji Electric

  • Aksesoris MCCB Internal for BW125, BW160, BW250 Fuji Electric
    • Auxiliary Switch (Type W)
      This switch is used for indicator lamp or control circuit
    • Alarm Switch (Type K)
      This switch can be connected to a warning lamp or buzzer to indicate when the breaker has been tripped.
    • Shunt Trip Device
      The purpose of this accessory is to trip the breaker from a distance.
    • Undervoltage Trip Device (Type R)
      The device is designed to protect circuits from harmful voltage drops. It can also be used for remote control purposes. The trip operates when the voltage drops to less than 70% of nominal coil rating, and the breaker cannot be reset until the voltage recovers 85% of its normal rating.
    • Terminal Block ( Type A) 
      A wiring terminal for internal accessories (Factory-mounted)
  • Aksesoris MCCB Internal for BW400, BW600, BW800 Fuji Electric
    • Alarm Switch (Type K)
      This switch can be connected to a warning lamp or buzzer to indicate when the breaker has been tirpped.
    • Shunt Trip Device (Type F)
      The puspose of this accessory is to trip the breaker from a distance.
    • Terminal Block (Type A)
      A wiring terminal for internal accessories (Factory Mounted)
    • Auxiliary Switch (Type W)
      This switch is used for indicator lamp or control circuit.
    • Undervoltage Trip Device (Type R)
      The devices is designed to protect circuits from harmful voltage drops. It can also be used for remote control purposes. The trip operates when the voltage drops to less than 70% of nominal coil rating, and breaker cannot be reset until the voltage recovers 85% of its normal rating.

12.    Aksesoris MCCB External 32AF – 800AF Fuji Electric

  • External Operating Handles
  • Interphase barrier (Terminal Cover Long Type and Terminal Cover Short Type)
  • Steel Enclosures
  • Mechanical Interlock Device
  • Motor-Operating Mechanism
  • Handle Locking Cover (L1)
  • Padlocking Device ( Cap Type Q1, QN) and Plate Type (Q2)