| Supporting protocol for IEC 60870 |
FALSE |
| Supporting protocol for DNP3 |
FALSE |
| Number of interfaces PROFINET |
0 |
| Number of HW-interfaces parallel |
0 |
| Supporting protocol for SERCOS |
FALSE |
| Number of HW-interfaces other |
0 |
| Number of HW-interfaces USB |
1 |
| SIL according to IEC 61508 |
None |
| Number of relay outputs |
0 |
| With optical interface |
FALSE |
| Max. number of time switches |
0 |
| System accessory |
FALSE |
| Additional program memory possible |
TRUE |
| Number of HW-interfaces wireless |
0 |
| Performance level according to EN ISO 13849-1 |
None |
| Certified for UL hazardous location division 2 |
FALSE |
| Radio standard GPRS |
FALSE |
| Height |
90 Millimetre |
| Supporting protocol for INTERBUS-Safety |
FALSE |
| Certified for UL hazardous location class I |
FALSE |
| Certified for UL hazardous location class III |
FALSE |
| Certified for UL hazardous location division 1 |
FALSE |
| Certified for UL hazardous location class II |
FALSE |
| Width |
150 Millimetre |
| Supporting protocol for EtherCAT |
FALSE |
| Redundancy |
FALSE |
| Supporting protocol for AS-Interface Safety at Work |
FALSE |
| Explosion safety category for dust |
None |
| Radio standard GSM |
FALSE |
| Radio standard UMTS |
FALSE |
| Depth |
95 Millimetre |
| Explosion safety category for gas |
None |
| Supporting protocol for DeviceNet Safety |
FALSE |
| Supporting protocol for EtherNet/IP |
TRUE |
| Supporting protocol for Foundation Fieldbus |
FALSE |
| Certified for UL hazardous location group C (ethylene) |
FALSE |
| Certified for UL hazardous location group A (acetylene) |
FALSE |
| Certified for UL hazardous location group B (hydrogen) |
FALSE |
| Certified for UL hazardous location group F (carbonaceous dusts) |
FALSE |
| Certified for UL hazardous location group G (non-conductive dusts) |
FALSE |
| Certified for UL hazardous location group D (propane) |
FALSE |
| Certified for UL hazardous location group E (metal dusts) |
FALSE |
| With display |
FALSE |
| Model |
Compact |
| Processing time (1K, binary operation) |
0.022 Millisecond |
| Supporting protocol for SafetyBUS p |
FALSE |
| Voltage type (supply voltage) |
DC |
| Type of memory |
NVRAM |
| Long-Term Evolution (LTE) |
FALSE |
| Supporting protocol for PROFINET CBA |
FALSE |
| Supporting protocol for PROFINET IO |
FALSE |
| Memory size |
64000 kiloByte (1000 Byte) |
| Supporting protocol for PROFIsafe |
FALSE |
| Radio standard Bluetooth |
FALSE |
| Supporting protocol for ASI |
FALSE |
| Supporting protocol for PROFIBUS |
FALSE |
| Appendant operation agent (Ex ia) |
FALSE |
| Radio standard WLAN 802.11 |
FALSE |
| Front built-in possible |
FALSE |
| Supporting protocol for TCP/IP |
TRUE |
| Supporting protocol for KNX |
FALSE |
| Supporting protocol for CAN |
TRUE |
| Appendant operation agent (Ex ib) |
FALSE |
| IO link master |
FALSE |
| Supporting protocol for INTERBUS |
FALSE |
| Supporting protocol for IEC 61850 Ethernet |
FALSE |
| Rail mounting possible |
TRUE |
| Supporting protocol for DeviceNet |
FALSE |
| Suitable for safety functions |
FALSE |
| Supporting protocol for Modbus |
TRUE |
| Number of digital outputs |
10 |
| Number of digital inputs |
14 |
| Supporting protocol for Data-Highway |
FALSE |
| Number of analogue outputs |
0 |
| Supply voltage DC |
19.2…28.8 Volt |
| Number of analogue inputs |
0 |
| Rack-assembly possible |
FALSE |
| Supporting protocol for LON |
FALSE |
| Supporting protocol for other bus systems |
FALSE |
| Supporting protocol for SUCONET |
FALSE |
| Number of HW-interfaces RS-422 |
0 |
| Wall mounting/direct mounting |
TRUE |
| Number of HW-interfaces RS-485 |
2 |
| Number of HW-interfaces industrial Ethernet |
1 |
| Number of HW-interfaces RS-232 |
2 |