This TM241 controller is part of the Modicon M241 Logic controller range. It has 24 logic I/O and it is supplied with 24V dc. It is supplied with removable screw terminal blocks for connecting the I/O, a removable terminal block for connecting the power supply, a button cell backup battery BR2032. This M241 logic controller has 5 embedded communication ports, two serial links (RS232/RS485 and RS485) and USB mini-B programming port. It also has an Ethernet port and a CANopen port. It enables the control of simple movements or of control loops. The capacity of M221 logic controllers can be enhanced with the Modicon TM3 expansion module offer.

Specification
Supporting protocol for IEC 60870 FALSE
Supporting protocol for DNP3 FALSE
Number of interfaces PROFINET 0
Number of HW-interfaces parallel 0
Supporting protocol for SERCOS FALSE
Number of HW-interfaces other 0
Number of HW-interfaces USB 1
SIL according to IEC 61508 None
Number of relay outputs 0
With optical interface FALSE
Max. number of time switches 0
System accessory FALSE
Additional program memory possible TRUE
Number of HW-interfaces wireless 0
Performance level according to EN ISO 13849-1 None
Certified for UL hazardous location division 2 FALSE
Radio standard GPRS FALSE
Height 90 Millimetre
Supporting protocol for INTERBUS-Safety FALSE
Certified for UL hazardous location class I FALSE
Certified for UL hazardous location class III FALSE
Certified for UL hazardous location division 1 FALSE
Certified for UL hazardous location class II FALSE
Width 150 Millimetre
Supporting protocol for EtherCAT FALSE
Redundancy FALSE
Supporting protocol for AS-Interface Safety at Work FALSE
Explosion safety category for dust None
Radio standard GSM FALSE
Radio standard UMTS FALSE
Depth 95 Millimetre
Explosion safety category for gas None
Supporting protocol for DeviceNet Safety FALSE
Supporting protocol for EtherNet/IP TRUE
Supporting protocol for Foundation Fieldbus FALSE
Certified for UL hazardous location group C (ethylene) FALSE
Certified for UL hazardous location group A (acetylene) FALSE
Certified for UL hazardous location group B (hydrogen) FALSE
Certified for UL hazardous location group F (carbonaceous dusts) FALSE
Certified for UL hazardous location group G (non-conductive dusts) FALSE
Certified for UL hazardous location group D (propane) FALSE
Certified for UL hazardous location group E (metal dusts) FALSE
With display FALSE
Model Compact
Processing time (1K, binary operation) 0.022 Millisecond
Supporting protocol for SafetyBUS p FALSE
Voltage type (supply voltage) DC
Type of memory NVRAM
Long-Term Evolution (LTE) FALSE
Supporting protocol for PROFINET CBA FALSE
Supporting protocol for PROFINET IO FALSE
Memory size 64000 kiloByte (1000 Byte)
Supporting protocol for PROFIsafe FALSE
Radio standard Bluetooth FALSE
Supporting protocol for ASI FALSE
Supporting protocol for PROFIBUS FALSE
Appendant operation agent (Ex ia) FALSE
Radio standard WLAN 802.11 FALSE
Front built-in possible FALSE
Supporting protocol for TCP/IP TRUE
Supporting protocol for KNX FALSE
Supporting protocol for CAN TRUE
Appendant operation agent (Ex ib) FALSE
IO link master FALSE
Supporting protocol for INTERBUS FALSE
Supporting protocol for IEC 61850 Ethernet FALSE
Rail mounting possible TRUE
Supporting protocol for DeviceNet FALSE
Suitable for safety functions FALSE
Supporting protocol for Modbus TRUE
Number of digital outputs 10
Number of digital inputs 14
Supporting protocol for Data-Highway FALSE
Number of analogue outputs 0
Supply voltage DC 19.2…28.8 Volt
Number of analogue inputs 0
Rack-assembly possible FALSE
Supporting protocol for LON FALSE
Supporting protocol for other bus systems FALSE
Supporting protocol for SUCONET FALSE
Number of HW-interfaces RS-422 0
Wall mounting/direct mounting TRUE
Number of HW-interfaces RS-485 2
Number of HW-interfaces industrial Ethernet 1
Number of HW-interfaces RS-232 2