Spesifikasi LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 230 V AC 50/60 Hz coil
"Download datasheet produk, click here!" "Download Catalog, click here!" "Download User Guide, click here!"
Main : range : TeSys product name : TeSys D product or component type : Contactor device short name : LC1D contactor application : Resistive load : Motor control utilisation category : AC-1 : AC-3 : AC-4 poles description : 3P power pole contact composition : 3 NO [Ue] rated operational voltage : Power circuit: <= 690 V AC 25...400 Hz : Power circuit: <= 300 V DC [Ie] rated operational current : 32 A (at <60 °C) at <= 440 V AC AC-3 for power circuit : 50 A (at <60 °C) at <= 440 V AC AC-1 for power circuit motor power kW : 7.5 kW at 220...230 V AC 50/60 Hz (AC-3) : 15 kW at 380...400 V AC 50/60 Hz (AC-3) : 15 kW at 415...440 V AC 50/60 Hz (AC-3) : 18.5 kW at 500 V AC 50/60 Hz (AC-3) : 18.5 kW at 660...690 V AC 50/60 Hz (AC-3) : 7.5 kW at 400 V AC 50/60 Hz (AC-4) motor power HP (UL / CSA) : 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors : 10 hp at 230/240 V AC 50/60 Hz for 3 phases motors : 30 hp at 575/600 V AC 50/60 Hz for 3 phases motors : 2 hp at 115 V AC 50/60 Hz for 1 phase motors : 7.5 hp at 200/208 V AC 50/60 Hz for 3 phases motors : 20 hp at 460/480 V AC 50/60 Hz for 3 phases motors control circuit type : AC at 50/60 Hz [Uc] control circuit voltage : 230 V AC 50/60 Hz auxiliary contact composition : 1 NO + 1 NC [Uimp] rated impulse withstand voltage : 6 kV conforming to IEC 60947 overvoltage category : III [Ith] conventional free air thermal current : 10 A (at 60 °C) for signalling circuit : 50 A (at 60 °C) for power circuit Irms rated making capacity : 140 A AC for signalling circuit conforming to IEC 60947-5-1 : 250 A DC for signalling circuit conforming to IEC 60947-5-1 : 550 A at 440 V for power circuit conforming to IEC 60947 rated breaking capacity : 550 A at 440 V for power circuit conforming to IEC 60947 [Icw] rated short-time withstand current : 60 A 40 °C - 10 min for power circuit : 138 A 40 °C - 1 min for power circuit : 260 A 40 °C - 10 s for power circuit : 430 A 40 °C - 1 s for power circuit : 100 A - 1 s for signalling circuit : 120 A - 500 ms for signalling circuit : 140 A - 100 ms for signalling circuit associated fuse rating : 10 A gG for signalling circuit conforming to IEC 60947-5-1 : 63 A gG at <= 690 V coordination type 1 for power circuit : 63 A gG at <= 690 V coordination type 2 for power circuit average impedance : 2 mOhm - Ith 50 A 50 Hz for power circuit [Ui] rated insulation voltage : Power circuit: 600 V CSA certified : Power circuit: 600 V UL certified : Signalling circuit: 690 V conforming to IEC 60947-1 : Signalling circuit: 600 V CSA certified : Signalling circuit: 600 V UL certified : Power circuit: 690 V conforming to IEC 60947-4-1 electrical durability : 1.65 Mcycles 32 A AC-3 at Ue <= 440 V : 1.4 Mcycles 50 A AC-1 at Ue <= 440 V power dissipation per pole : 2 W AC-3 : 5 W AC-1 Front cover : With mounting support : Rail : Plate standards : CSA C22.2 No 14 : EN 60947-4-1 : EN 60947-5-1 : IEC 60947-4-1 : IEC 60947-5-1 : UL 508 product certifications : UL : GOST : CSA : BV : LROS (Lloyds register of shipping) : RINA : GL : CCC : DNV connections - terminals : Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end : Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end : Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end : Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end : Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end : Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end : Power circuit: screw clamp terminals 1 cable(s) 2.5…10 mm²flexible without cable end : Power circuit: screw clamp terminals 2 cable(s) 2.5…10 mm²flexible without cable end : Power circuit: screw clamp terminals 1 cable(s) 1…10 mm²flexible with cable end : Power circuit: screw clamp terminals 2 cable(s) 1.5…6 mm²flexible with cable end : Power circuit: screw clamp terminals 1 cable(s) 1.5…10 mm²solid without cable end : Power circuit: screw clamp terminals 2 cable(s) 2.5…10 mm²solid without cable end tightening torque : Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm : Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 : Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm : Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2 operating time : 4...19 ms opening : 12...22 ms closing safety reliability level : B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 : B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 mechanical durability : 15 Mcycles maximum operating rate : 3600 cyc/h 60 °C Complementary : coil technology : Without built-in suppressor module control circuit voltage limits : 0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz : 0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz : 0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz : 1...1.1 Uc (60…70 °C):operational AC 50/60 Hz inrush power in VA : 70 VA 60 Hz cos phi 0.75 (at 20 °C) : 70 VA 50 Hz cos phi 0.75 (at 20 °C) hold-in power consumption in VA : 7.5 VA 60 Hz cos phi 0.3 (at 20 °C) : 7 VA 50 Hz cos phi 0.3 (at 20 °C) heat dissipation : 2…3 W at 50/60 Hz auxiliary contacts type : type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 : type mirror contact 1 NC conforming to IEC 60947-4-1 signalling circuit frequency : 25...400 Hz minimum switching current : 5 mA for signalling circuit minimum switching voltage : 17 V for signalling circuit non-overlap time : 1.5 ms on de-energisation between NC and NO contact : 1.5 ms on energisation between NC and NO contact insulation resistance : > 10 MOhm for signalling circuit Environment : IP degree of protection : IP20 front face conforming to IEC 60529 protective treatment : TH conforming to IEC 60068-2-30 pollution degree : 3 ambient air temperature for operation : -40…60 °C : 60…70 °C with derating ambient air temperature for storage : -60…80 °C operating altitude : 0...3000 m fire resistance : 850 °C conforming to IEC 60695-2-1 flame retardance : V1 conforming to UL 94 mechanical robustness : Vibrations contactor open: 2 Gn, 5...300 Hz : Vibrations contactor closed: 4 Gn, 5...300 Hz : Shocks contactor closed: 15 Gn for 11 ms : Shocks contactor open: 8 Gn for 11 ms height : 85 mm width : 45 mm depth : 92 mm net weight : 0.375 kg
Packing Units : Unit Type of Package 1 : PCE Number of Units in Package 1 : 1 Package 1 Weight : 414 g Package 1 Height : 5 cm Package 1 width : 9.2 cm Package 1 Length : 11.2 cm Unit Type of Package 2 : S02 Number of Units in Package 2 : 20 Package 2 Weight : 8.775 kg Package 2 Height : 15 cm Package 2 width : 30 cm Package 2 Length : 40 cm Unit Type of Package 3 : P06 Number of Units in Package 3 : 320 Package 3 Weight : 148.26 kg Package 3 Height : 80 cm Package 3 width : 80 cm Package 3 Length : 60 cm Offer Sustainability : Sustainable offer status : Green Premium product REACh Regulation : REACh Declaration REACh free of SVHC : Yes EU RoHS Directive : Compliant : EU RoHS Declaration Toxic heavy metal free : Yes Mercury free : Yes RoHS exemption information : Yes China RoHS Regulation : China RoHS declaration : Pro-active China RoHS declaration (out of China RoHS legal scope) Environmental Disclosure : Product Environmental Profile Circularity Profile : End of Life Information WEEE : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins PVC free : Yes
Contractual warranty : Warranty : 12 months