TESYS D SCHNEIDER ELECTRIC - LC1D25EHE
Arus Pengenal (Rated Current)  : 25A
Tegangan Coil (Control Circuit Voltage)  : 48 - 130V AC/DC
Motor Power kW  : 11kW
Rp. 1.801.800,-
Rp. 1.081.080,-
Chat for Stok

Spesifikasi LC1D25EHE TeSys D contactor 3P 25A AC-3 up to 440V coil 48-130V AC/DC

"Download datasheet produk, click here!"
"Download Catalog, click here!"
"Download User Guide, click here!"

Main : 
range : TeSys
product name : TeSys D Green
product or component type : Contactor
device short name : LC1D
contactor application : Motor control
 : Resistive load
utilisation category : AC-3
 : AC-1
poles description : 3P
power pole contact composition : 3 NO
[Ue] rated operational voltage : Power circuit: <= 690 V AC 25...400 Hz
[Ie] rated operational current : 25 A (at <60 °C) at <= 440 V AC-3 for power circuit
 : 40 A (at <60 °C) at <= 440 V AC-1 for power circuit
motor power kW : 5.5 kW at 220...230 V AC 50 Hz (AC-3)
 : 11 kW at 380...400 V AC 50 Hz (AC-3)
 : 11 kW at 415 V AC 50 Hz (AC-3)
 : 11 kW at 440 V AC 50 Hz (AC-3)
 : 15 kW at 500 V AC 50 Hz (AC-3)
 : 15 kW at 660...690 V AC 50 Hz (AC-3)
motor power HP (UL / CSA) : 2 hp at 115 V AC 60 Hz for 1 phase motors
 : 3 hp at 230/240 V AC 60 Hz for 1 phase motors
 : 7.5 hp at 200/208 V AC 60 Hz for 3 phases motors
 : 7.5 hp at 230/240 V AC 60 Hz for 3 phases motors
 : 15 hp at 460/480 V AC 60 Hz for 3 phases motors
 : 20 hp at 575/600 V AC 60 Hz for 3 phases motors
[Uc] control circuit voltage : 48...130 V AC 50/60 Hz
 : 48...130 V DC
coil type : AC/DC electronic
auxiliary contact composition : 1 NO + 1 NC
[Uimp] rated impulse withstand voltage : 6 kV conforming to IEC 60947
overvoltage category : III
[Ith] conventional free air thermal current : 10 A (at 60 °C) for signalling circuit
 : 40 A (at 60 °C) for power circuit
Irms rated making capacity : 140 A AC for signalling circuit conforming to IEC 60947-5-1
 : 250 A DC for signalling circuit conforming to IEC 60947-5-1
 : 450 A at 440 V for power circuit conforming to IEC 60947
rated breaking capacity : 450 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current : 100 A - 1 s for signalling circuit
 : 120 A - 500 ms for signalling circuit
 : 140 A - 100 ms for signalling circuit
 : 50 A 40 °C - 10 min for power circuit
 : 120 A 40 °C - 1 min for power circuit
 : 240 A 40 °C - 10 s for power circuit
 : 380 A 40 °C - 1 s for power circuit
associated fuse rating : 10 A gG for signalling circuit conforming to IEC 60947-5-1
 : 63 A gG at <= 690 V coordination type 1 for power circuit
 : 40 A gG at <= 690 V coordination type 2 for power circuit
average impedance : 2 mOhm - Ith 40 A 50 Hz for power circuit
[Ui] rated insulation voltage : Power circuit: 690 V conforming to IEC 60947-4-1
 : Signalling circuit: 690 V conforming to IEC 60947-1
electrical durability : 2 Mcycles 21 A AC-3 at Ue <= 440 V
 : 0.9 Mcycles 40 A AC-1 at Ue <= 440 V
power dissipation per pole : 3.2 W AC-1
 : 1.25 W AC-3
Front cover : With
mounting support : Plate
 : Rail
standards : EN/IEC 60947-4-1
 : EN/IEC 60947-5-1
 : UL 60947-4-1
 : CSA C22.2 No 60947-4-1
product certifications : CCC
 : CSA
 : EAC
 : UL
 : KC
 : DNV-GL
 : LROS (Lloyds register of shipping)
connections - terminals : Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
 : Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
 : Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
 : Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
 : Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid
 : Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid
 : Power circuit: screw clamp terminals 1 cable(s) 2.5…10 mm²flexible without cable end
 : Power circuit: screw clamp terminals 2 cable(s) 2.5…10 mm²flexible without cable end
 : Power circuit: screw clamp terminals 1 cable(s) 1…10 mm²flexible with cable end
 : Power circuit: screw clamp terminals 2 cable(s) 1.5…6 mm²flexible with cable end
 : Power circuit: screw clamp terminals 1 cable(s) 1.5…10 mm²solid
 : Power circuit: screw clamp terminals 2 cable(s) 2.5…10 mm²solid
tightening torque : Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
 : Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
 : Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
 : Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2
operating time : 45...55 ms closing
 : 20...90 ms opening
safety reliability level : B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
 : B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
mechanical durability : 15 Mcycles
maximum operating rate : 3600 cyc/h 60 °C
Complementary : 
coil technology : Built-in bidirectional peak limiting
control circuit voltage limits : <= 0.1 Uc (-40…70 °C):drop-out AC/DC
 : 0.85...1.1 Uc (-40…60 °C):operational AC/DC
 : 1...1.1 Uc (60…70 °C):operational AC/DC
inrush power in VA : 25 VA 50/60 Hz (at 20 °C)
inrush power in W : 24 W at 20 °C
hold-in power consumption in VA : 1.3 VA (at 20 °C) 50/60 Hz
hold-in power consumption in W : 0.8 W at 20 °C
heat dissipation : 0.8 W at 50/60 Hz
auxiliary contacts type : type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
 : type mirror contact 1 NC conforming to IEC 60947-4-1
signalling circuit frequency : 25...400 Hz
minimum switching current : 5 mA for signalling circuit
minimum switching voltage : 17 V for signalling circuit
non-overlap time : 1.5 ms on de-energisation between NC and NO contact
 : 1.5 ms on energisation between NC and NO contact
insulation resistance : > 10 MOhm for signalling circuit
Environment : 
IP degree of protection : IP20 front face conforming to IEC 60529
protective treatment : TH conforming to IEC 60068-2-30
pollution degree : 3
ambient air temperature for operation : -40…60 °C
 : 60…70 °C with derating
ambient air temperature for storage : -60…80 °C
operating altitude : 0...3000 m
fire resistance : 850 °C conforming to IEC 60695-2-1
flame retardance : V1 conforming to UL 94
mechanical robustness : Vibrations contactor open: 2 Gn, 5...300 Hz
 : Vibrations contactor closed: 4 Gn, 5...300 Hz
 : Shocks contactor closed: 15 Gn for 11 ms
 : Shocks contactor open: 8 Gn for 11 ms
height : 85 mm
width : 45 mm
depth : 92 mm
net weight : 0.433 kg
colour : Grey (SE GREY 6)
 : Green (SE GREEN 2)

Packing Units : 
Package 1 Weight : 0.460 kg
Package 1 Height : 0.550 dm
Package 1 width : 0.950 dm
Package 1 Length : 1.180 dm
Offer Sustainability : 
Sustainable offer status : Green Premium product
REACh Regulation : REACh Declaration
EU RoHS Directive : Compliant
 : EU RoHS Declaration
Mercury free : Yes
RoHS exemption information : Yes
China RoHS Regulation : China RoHS declaration
 : Product out of China RoHS scope. Substance declaration for your information
Environmental Disclosure : Product Environmental Profile
Circularity Profile : End of Life Information
WEEE : The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Halogen content performance : Halogen free plastic parts & cables product

Contractual warranty : 
Warranty : 18 months