VigiPacT RH99M is a DIN rail mounting residual current protection relay. It protects against people direct or indirect contact, property fire hazards and motors. It measures the earth leakage current in an electrical installation via its associated toroid. It trips the associated circuit breaker when the set residual operation current is overrun. The operational supply voltage is 220/240VAC 50/60Hz. The current sensitivity is selectable with 9 thresholds from 30 mA to 30 A. The time delay is selectable with 9 settings from instantaneous to 4.5s. It requires a local manual reset after a fault clearance. The monitored distribution system voltage is up to 1000 VAC 50/60/400 Hz. It is installed on a DIN-rail inside a switchboard and the protection degree is IP40. It must be associated with a compatible Schneider Electric type A toroid or rectangular sensor.

Specification
Current measuring range 0.015…60 Milliampere
Type of electric connection Screw connection
Voltage type (supply voltage) AC
Error registration possible FALSE
Indication of difference current FALSE
Voltage type (operating voltage) AC
Supply voltage AC 50 Hz 220…240 Volt
Supply voltage AC 60 Hz 220…240 Volt
External power supply required TRUE
Response value amperage 1 0.03…30 Milliampere
Height 97 Millimetre
Max. permitted delay-on energization time 4.82 Second
Width 54 Millimetre
Rated switch current 8 Ampere
Voltage measuring range 0…1000 Volt
Operating voltage AC 50 Hz 220…240 Volt
Depth 74 Millimetre
Operating voltage AC 60 Hz 220…240 Volt
Number of contacts as normally open contact 1
Rated operating frequency 50…400 Hertz
Number of contacts as change-over contact 1
Function For AC-current system
Number of contacts as normally closed contact 0
With detachable clamps FALSE
Min. adjustable delay-on energization time 0 Second